PilotFish Interface Exchange (PIE)

A marketplace for eiConsole (IDE) interface templates, components and industry bundles
eiConsole IDE 90-Day Free Trial!
The PIE makes it easy to collaborate and share eiConsole. Interfaces templates and components. Follow the eiConsole Assembly and configure interfaces with no coding or scripting. Then using the PIE Wizard publish and share them on the PIE in just minutes. Charge a fee or make them available for free. Everything you need is provided.

HL7 V2.x Template: Laboratory: Reporting to EHR ORU_R01 Culture Report

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: Laboratory: Reporting to EHR ORU_R01 Culture Report This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 Culture Report message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Orders and Observations; Interoperable Laboratory Result Reporting to EHR, Release 1". This message is used by an EHR to read a culture report from a laboratory. More...

HL7 V2.x Template: Laboratory: Reporting to EHR ORU_R01 Creatinine Clearance

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: Laboratory: Reporting to EHR ORU_R01 Creatinine Clearance This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 Creatinine Clearance message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Orders and Observations; Interoperable Laboratory Result Reporting to EHR, Release 1". This message is used by an EHR to read a Creatinine Clearance report from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Susceptibility Results

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Susceptibility Results This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 susceptibility results message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release 1". This message is used by an EHR to read a susceptibility results report from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Minimal Message

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Minimal Message This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 minimal message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release ". This message is used by a public health agency to read a minimal message from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Lead Lab Result

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Lead Lab Result This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 lead lab result message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release 1". This message is used by an EHR to read a lead lab result report from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Identified Pathogens

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Identified Pathogens This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 identified pathogens message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release 1". This message is used by a public health agency to read an identified pathogens report from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Hepatitis C

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Hepatitis C This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 hepatitis C message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release 1". This message is used by a public health agency to read a hepatitis C report from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Campylobacter Jejuni

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Campylobacter Jejuni This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 campylobacter jejuni message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release 1". This message is used by a public health agency to read a campylobacter jejuni report from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Animal Rabies

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to Public Health ORU_R01 Animal Rabies This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 animal rabies message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Electronic Laboratory Reporting to Public Health, Release 1". This message is used by a public health agency to read an animal rabies report from a laboratory. More...

HL7 V2.x Template: HHSFR: Reporting to EHR ORU_R01 Identified Pathogens

  • Associated industry: Healthcare
  • Associated application: PilotFish eiConsole

HL7 V2.x Template: HHSFR: Reporting to EHR ORU_R01 Identified Pathogens This interface offers a bundle of two HL7 interface templates intended to support the integration of systems using the ORU_R01 Identified Pathogens message as described in the implementation guide: "HL7 Version 2.5.1 Implementation Guide: Orders and Observations; Interoperable Laboratory Result Reporting to EHR, Release 1". This message is used by an EHR to read an identified pathogens report from a laboratory. More...